Sample report: this is the ‘key to this report’
and the structural section from an actual recent
report. The names have been changed to protect the
innocent.
For the purposes of this report, I’ll refer to the
left, rear, right and front when facing the home
from the street. I’ll call the bedrooms the front,
rear and master, and I’ll call the area behind the
garage the shop.
This report contains a lot of information, more than
some homeowners want to know. For example, most
people want to know if the deck is well built but
don’t really care if the joists are 2x8 or 2x10.
I’ve tried to make the report as ‘readable’ as
possible. Each system (Structural, Roof, etc.) will
start on a new page. Each page will follow the same
format and have the same sections. There are five
sections in the following order:
Description of….: Specific information such
as the manufacturer, size, location, etc.
General Comments: General and specific
information on the system.
Recommendations/Observations: Observations or
recommended improvements. For your convenience, all
the items in this section will be preceded by one of
the following symbols:
-
improvement needed: improvements that should be
anticipated over the short term. These may be
items that the typical homeowner can do, such as
changing a dirty furnace filter or minor site
drainage improvements. These items may also
require a professional, but it should not be a
major expense.
-
monitor/observation:
This symbol is used for items where further
monitoring is needed. Repairs may be necessary.
During the inspection, there was insufficient
information; improvements cannot be determined
until further investigation or observations are
made. This symbol is also used for an observation
of a condition that is not usually repaired, such
as common cracks in concrete surfaces.
-
There may also be a
section labeled “Discretionary Improvements”.
These are not essential repairs, but represent
logical long term improvements.
Maintenance Information: This section is the
same in every report, and I hope you find it
helpful. Often this section will help explain items
in the General Comments or
Recommendations/Observations sections. The
maintenance tips will refer to the systems and
components I find most often in our area. If your
home has an unusual feature or system there will
likely be additional maintenance information in the
General Comments. I have included some definitions
of words or items that appear frequently in reports.
The defined words or items are italicized and
appear at the end of the maintenance section.
Limitations: Items that are outside the scope
of the inspection or were not visible. Some of these
will be specific to your home, such as a garage that
was not visible because of stored items. Some of
these are general limitations that appear in every
report and may not be applicable to your home.
Once again, my goal is to make the report as
informative and helpful as possible. If I make a
recommendation, I try to explain the item in detail
and explain why it’s a problem (if it’s not
obvious). I may offer suggestions on improving or
repairing the item. I will try to do this in
everyday language and not impress you with my
construction vocabulary.
Structural Components
description of structural components
Foundation:
·Concrete
·Crawl Space
Configuration ·Crawl
Space Access: Exterior ·Crawl
Space Moisture Barrier: None (typical)
·Crawl Space
Method Of Inspection: Entered
Floor Structure:
·2x10 Wood Floor
Joist ·4x4 Wood
Columns ·4x12 Wood
Floor Beams ·Plywood
Sub Floor
Wall Structure:
·Wood Frame
Ceiling Structure:
·2x4 Trusses
Roof Structure:
·2x4 Trusses
Roof Sheathing:
·Plywood
Attic Access
Location: ·Closet
·Attic Method Of
Inspection: Entered - Inaccessible Areas
general comments
This is a one level home built over a crawlspace.
The foundation is in very good condition; only a
very few common cracks were noted in the foundation
walls. The condition of the windows and exterior
indicates there has been no abnormal settlement of
the foundation.
The crawlspace is accessed at the rear exterior.
Movement in the crawlspace is tight but all areas
can be reached. Overall the crawlspace framing is in
good condition. The floor joists are supported by
two full length beams. The 4x4 posts are on concrete
pads; no wood/soil contact was noted at the
crawlspace framing. Framing straps and anchor bolts
are properly installed. The condition of the
interior doors, walls, etc. indicates there has been
no major settlement of the crawlspace framing.
The attic is accessed from the master bedroom
closet. Movement in the main attic is pretty easy
(for an attic). There is no access to the attic over
the family room. The attic framing is very good, and
no signs of active roof leaks were noted.
Overall, the construction of the home is considered
to be good quality. The materials and workmanship,
where visible, are above average. No major defects
were observed in the accessible structural
components of the house.
recommendations / observations
-
Common cracks were
observed in the foundation and stem (block) walls
of the house. This implies that some structural
movement of the building has occurred, as is
typical of most houses, and is not a structural
concern. We find common cracks in most of the
homes we inspect. It doesn’t hurt to seal (caulk,
etc.) any cracks that are large enough to need it.
Cracks should be monitored, of course; if further
movement is noted additional investigation may be
needed.
-
All wood debris and wood items stored directly on
the soil should be removed from the crawl space.
Any wood in contact with the soil may attract wood
destroying insects.
-
The crawlspace access door is loose and very hard
to close. The 2x6 the door hinges attach to is
loose. The debris needs to be removed from between
the 2x6 and the block wall so the 2x6 can be
tightened.
maintenance information
The most important
maintenance concerning the structural components is
to keep moisture out of the home; also see the
maintenance tips in the Roof and Exterior sections.
If you suspect you are developing structural
problems you should consult with a qualified
contractor. Often there is a cause that can be
corrected easily, such as a leaking roof or a broken
downspout. It is important to keep surface water
away from the home, and it is also important to
avoid wood/soil contact around the home or in the
crawlspace. This includes storing wood items on the
ground; any wood that is in contact with the soil
and the home is a possible entry point for wood
destroying insects.
Component: One
part of a system, for example the foundation is only
one component in the structural system.
System: A
complete system consists of many components; for
example the structural system consists of components
including the foundation, stem and exterior walls,
roof structure, etc. These two terms apply to all
the systems; heating, plumbing, etc.
Foundation: The
base structure supporting the home. The foundation
is usually concrete.
Stem walls: The
walls above the foundation, usually concrete or
concrete block. The wood framing or exterior walls
are supported by the stem walls.
Truss: A
pre-manufactured structural element, usually of
wood, used for roof framing and sometimes for floor
joists.
Attic: The
space above the living area ceilings and under the
roof.
Crawlspace: The
area under the living area floor. There is no
crawlspace in a home built on a concrete slab.
limitations of structural component inspection
As
described in the inspection contract, this is a
visual inspection only. Assessing the structural
integrity of a building is beyond the scope of a
typical home inspection. A certified professional
engineer is recommended where there are structural
concerns about the building. Inspection of
structural components was limited by (but not
restricted to) the following conditions:
If you
would like a longer sample report, with more
sections, email us and we will be happy to send one
to you, preferably as a WORD attachment.
|
INSPECTING PRESCOTT
SINCE 1993 |
Professional Building Consultants, Inc.
PO Box 3560
Prescott, AZ 86302 |
Bus 928-445-4769
Fax 928-442-9426
E-Mail:
pbc@cableone.net |
|